Flygt 3000 series range of Submersible pumps

 

Flygt Pumps - A Xylem Brand Flygt BS 2870 Submersible Pumps

Flygt, a brand of Xylem, is synonymous with engineering excellence, reliability and closeness to customers.

Flygt is a world-leader in the design and manufacture of dry and submersible pumps, mixers and related intelligent controls systems.

Under the Flygt banner, customers have access to a complete range of products and solutions for moving water, wastewater, and advanced monitoring and control equipment to optimise their use.

Can't see the model you need? Call our Sales Team for expert advice on 01246 201111 or email at sales@marispumps.com

*Delivery charges may apply to Flygt products.

Flygt pump replacement form

View Details

Flygt NP3085 Submersible Pump

The Flygt N-Series 3085 is a low capacity self-cleaning submersible pump and is available in single phase (230V) or 3-phase (400V).

View Details

Flygt NP3102 Submersible Pump

The Flygt NP3102 is a low capacity self-cleaning submersible pump and is available in 3-phase (400V) with Medium Head (MT)

View Details

Flygt NP3127 Submersible Pump

The Flygt NP3127 is a low capacity self-cleaning submersible pump and is available in 3-phase (400V) with Medium Head (MT).

View Details

Flygt NP3153 Submersible Pump

The Flygt NP3153 is a low capacity self-cleaning submersible pump and is available in 3-phase (400V) with either Medium Head (MT) or High Head (HT).

View Details

Flygt CP3057 Submersible Pump

The Flygt CP3057 has a shrouded single-channel impeller pump with large throughlets and single volute pump casing for liquids containing solids and fibres and is available in single phase (220V) with High Head (HT).

View Details

Flygt MP3068 Submersible Pump

The Flygt MP3068 has an M impeller designed for pressurised sewage systems and is available in single phase (230V) and 3-phase (400V) with High Head (HT).

View Details

Flygt DP3068 Submersible Pump

The Flygt DP 3068 has a D impeller designed for solids handling and is available in single phase (230V) and 3-phase (400V) with Medium Head (MT).

Quote me a C 3085

Flygt C 3085

Flygt C 3085 Submersible Pumps Range Flygt C 3085 MT Submersible Pumps Range Flygt C 3085 HT Submersible Pumps Range
  • Discharge: 75mm
  • Height: 655 mm
  • Motor Rating: 2.0 kW
  • Weight: 71 kg
  • Max. Width: 638 mm
Impeller Code No. of Vanes Outlet Dia. mm CP Vers Through let, mm Motor Rating, kW rpm Available Versions
432 1 100 ⌀ 76 2.0 1400 CP/CS
252 1 80 ⌀ 40 2.4 2840 CP/CS
Quote me a C 3102

Flygt C 3102

Flygt C 3102 Submersible Pumps Range Flygt C 3102 MT Submersible Pumps Range Flygt C 3102 HT Submersible Pumps Range
  • Discharge: 75/100 mm
  • Height: 718 mm
  • Motor Rating: 3.1 kW
  • Weight: 116 kg
  • Max. Width: 640 mm
Impeller Code No. of Vanes Outlet Dia. mm CP Vers Through let, mm Motor Rating, kW rpm Available Versions
430 1 100 ⌀ 76 3.1 1400 CP/CS/MT
252 1 80 ⌀ 52 4.4 2850 CP/CS/MT
Quote me a C 3127

Flygt C 3127

Flygt C 3127 Submersible Pumps Range Flygt C 3127 MT Submersible Pumps Range Flygt C 3127 HT Submersible Pumps Range
  • Discharge: 100/150 mm
  • Height: 761 mm
  • Motor Rating: 5.9/7.4 kW
  • Weight: 175 kg
  • Max. Width: 780 mm
Impeller Code No. of Vanes Outlet Dia. mm CP Vers Through let, mm Motor Rating, kW rpm Available Versions
430 1 100/150 100x110 5.9 1400 CP/CS
250 HT 1 80 ⌀ 58 7.4 2900 CP/CS
Quote me a C 3152

Flygt C 3152

Flygt C 3152 Submersible Pumps Range Flygt C 3152 LT Submersible Pumps Range Flygt C 3152 HT Submersible Pumps Range
  • Discharge: 150/200 mm
  • Height: 1228 mm
  • Motor Rating: 13.5 kW
  • Weight: 426 kg
  • Max. Width: 900 mm
Impeller Code No. of Vanes Outlet Dia. mm CP Vers Through let, mm Motor Rating, kW rpm Available Versions
616 2 250 102x102 8.8 950 CP/CT/CS
430 1 250 100x115 13.5 1450 CP/CT/CS
452 HT 1 150 76x76 13.5 1450 CP/CT/CS
265 SH 1 100 40x40 150 2920 CP/CT/CS
Quote me a C 3201

Flygt C 3201

Flygt C 3201 Submersible Pumps Range Flygt C 3201 MT Submersible Pumps Range Flygt C 3201 HT Submersible Pumps Range
  • Discharge: 200/250 mm
  • Height: 1442 mm
  • Motor Rating: 30/22 kW
  • Weight: 588 kg
  • Max. Width: 1150 mm
Impeller Code No. of Vanes Outlet Dia. mm CP Vers Through let, mm Motor Rating, kW rpm Available Versions
630 1 250 144x120 22 965 CP/CT/CS
456 1 150 ⌀ 100 30 1250 CP/CT/CS
Quote me a C 3300

Flygt C 3300

Flygt C 3300 Submersible Pumps Range Flygt C 3300 MT & HT Submersible Pumps Range Flygt C 3300 HT Submersible Pumps Range
  • Discharge: 200/250 mm
  • Height: 1915 mm
  • Motor Rating: 54/44 kW
  • Weight: 1218 kg
  • Max. Width: 1624 mm
Impeller Code No. of Vanes Outlet Dia. mm CP Vers Through let, mm Motor Rating, kW rpm Available Versions
632 1 250 ⌀ 90 44 970 CP/CT/CS
452 1 150 96x96 54 1450 CP/CT/CS
620 3 300 ⌀ 102 44 975 CP/CT/CS

Impeller Explanation

C
Flygt 3000 C Impeller

C Pumps are equipped with a shrouded, single or multi-vane impeller that runs in a volute. The shape and size of the impeller is designed to minimise clogging, which makes this pump ideal for wastewater applications.

D
Flygt 3000 D Impeller

The D-Pump is used mainly to pump abrasive media or low volumes at high heads. This pump features a vortex impeller, which means that the flow is produced not by the impeller but by the rapidly rotating vortex the impeller creates. Consequently most of the particles in the liquid never come into actual contact with the impeller, thus minimising wear. These pumps have a comparably large throughlet.

M
Flygt 3000 M Impeller

Specially designed for pressurised sewage systems the M-Pump features an impeller that grinds solids to a fine slurry, which can then be pumped through narrow piping, measuring 32-50mm in diameter.

N
Flygt 3000 N Impeller

With its unique semi-open, self-cleaning impeller, the new series of N-Pumps can handle fluids with high concentrations of fibrous material, whilst maintaining a high level of pumping efficiency over long duty periods. The special relief groove in the volute reduces the risk of clogging by creating a self-cleaning flow path through the pump.

Applications

Irrigation

Application irrigation for Flygt pumps

The agricultural sector consumes approximately 70% worldwide which is the largest by far. These irrigation systems are used to pump water to the ground and to dry areas, especially during periods of inadequate precipitation.

Recommended Products for Irrigation

Channel Impeller Pumps
N-technology Pumps

Bypass

Application bypass for Flygt pumps

Temporary bypass pumping is frequently used during line replacement and pump station upgrade to ensure that the sewer system remains operational.

Recommended Products for Bypass

Channel Impeller Pumps
Vortex Impeller Pumps

RAS/WAS (Secondary Sludge Pumping)

Application sludge for Flygt pumps

Secondary sludge pumping (RAS/WAS) is a part of the treatment plant process. Return activated sludge (RAS) is constantly pumped back into the secondary biological treatment tank as part of the treatment process.

Recommended Products for Sludge

Channel Impeller Pumps
N-technology Pumps